Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/112304
Citations
Scopus Web of Science® Altmetric
?
?
Type: Conference item
Title: An evaluation of two methods to measure hemoglobin concentration among women with genetic hemoglobin disorders in Cambodia: a method-comparison study
Author: Karakochuk, C.
Janmohamed, A.
Whitfield, K.
Barr, S.
Vercauteren, S.
Kroeun, H.
Talukder, A.
McLean, J.
Green, T.
Citation: The FASEB Journal, 2015, vol.29, iss.1 Suppl.
Publisher: Federation of American Societies for Experimental Biolog
Issue Date: 2015
ISSN: 0892-6638
1530-6860
Conference Name: Experimental Biology Meeting (EB 2015) (28 Mar 2015 - 1 Apr 2015 : Boston, MA)
Statement of
Responsibility: 
Crystal Karakochuk, Amynah Janmohamed, Kyly Whitfield, Susan Barr, Suzanne Vercauteren, Hou Kroeun, Aminuzzaman Talukder, Judy McLean, and Timothy Green
Abstract: <jats:sec><jats:label /><jats:p>Genetic hemoglobin (Hb) E variants are common in Cambodia and result in an altered and unstable Hb molecule. There are no known studies on the accuracy of Hb measurement using these methods in individuals with Hb E variants.</jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>We measured Hb concentration in capillary blood using a hemoglobinometer (HemoCue) and in venous blood using a hematology analyzer (Sysmex XT‐1800i) in 420 Cambodian women (18‐45 y).</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>Bias and concordance appeared similar between methods among women with no Hb disorders (n=195, bias=2.5, p<jats:sub>c</jats:sub>=0.68), women with Hb E variants (n=133, bias=2.5, p<jats:sub>c</jats:sub>=0.78), and women with other Hb variants (n=92, bias=2.7, p<jats:sub>c</jats:sub>=0.73). The overall bias (difference in Hb means between methods) was 2.6 g/L , resulting in a difference in anemia prevalence of 11.5% (Hemocue 41% vs. Sysmex 29.5%, p &lt;0.001). Based on concordance plots, the HemoCue device appears to underestimate Hb concentrations in capillary blood as compared to Sysmex (venous blood) at lower Hb concentrations, and to overestimate Hb concentrations in capillary blood as compared to Sysmex at higher Hb concentrations.</jats:p></jats:sec><jats:sec><jats:title>Conclusions</jats:title><jats:p>Bias and concordance were similar among all groups, suggesting the two methods were comparable in measuring Hb among women in all groups. We highlight the bias between the two methods to caution programming staff, researchers, and policy makers in the interpretation of data and the impact that even a small bias can have on anemia prevalence rates.</jats:p></jats:sec>
Description: Published Online:1 Apr 2015. Abstract Number:403.1
Rights: © 2015 by the Federation of American Societies for Experimental Biology
DOI: 10.1096/fasebj.29.1_supplement.403.1
Published version: https://www.fasebj.org/doi/abs/10.1096/fasebj.29.1_supplement.403.1
Appears in Collections:Aurora harvest 3
Paediatrics publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.