Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/116231
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Impact of crystal orientation on the adsorption kinetics of a porous coordination polymer-quartz crystal microbalance hybrid sensor
Author: Hirai, K.
Sumida, K.
Meilikhov, M.
Louvain, N.
Nakahama, M.
Uehara, H.
Kitagawa, S.
Furukawa, S.
Citation: Journal of Materials Chemistry C, 2014; 2(17):3336-3344
Publisher: Royal Society of Chemistry
Issue Date: 2014
ISSN: 2050-7526
2050-7534
Statement of
Responsibility: 
Kenji Hirai, Kenji Sumida, Mikhail Meilikhov, Nicolas Louvain, Masashi Nakahama, Hiromitsu Uehara, Susumu Kitagawa and Shuhei Furukawa
Abstract: The hybridization of porous coordination polymers (PCPs) with electronic devices is a powerful strategy for developing systems that are suitable for advanced applications, such as chemical sensing. The quartz crystal microbalance (QCM) technique is one that allows minute mass changes to be resolved with a high temporal resolution, and the growth of PCP crystals that provide selective adsorption properties on a QCM substrate can facilitate the rapid detection of certain molecules from a gas or vapour mixture. Herein, we demonstrate the immobilization of the flexible PCP Zn(NO₂-ip)(bpy) (Zn-CID-5; NO₂-ip²⁻ = 5-nitroisophthalate, bpy = 4,4′-bipyridine) on QCM substrates and investigate the adsorptive properties of the fabricated systems. Notably, the crystal orientation could be controlled by the anchoring of chemical functionalities on the substrate surface, or by the addition of coordination modulators (e.g. 4-phenylpyridine) at the time of growth of the PCP crystals on the substrates. Here, the crystal orientation plays a significant role in determining the detection kinetics of organic vapours (e.g. methanol), and the [010]-oriented case which displays the fastest adsorption kinetics among the samples tested is studied under mixed component (methanol–hexane) conditions to demonstrate its response profile. In all, the results demonstrate the potential utility of PCP/QCM hybrid systems in sensor applications, and also serve to highlight the importance of optimizing the physical orientation of crystal growth in such systems to maximize the overall performance of the system.
Rights: This journal is © The Royal Society of Chemistry 2014
DOI: 10.1039/c3tc32101k
Published version: http://dx.doi.org/10.1039/c3tc32101k
Appears in Collections:Aurora harvest 8
Chemistry publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.