Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/136616
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Active Air-borne noise suppression for pipe break early warning in smart water networks
Author: Zeng, W.
Cazzolato, B.
Lambert, M.
Gong, J.
Stephens, M.
Citation: Applied Acoustics, 2022; 198:1-11
Publisher: Elsevier
Issue Date: 2022
ISSN: 0003-682X
1872-910X
Statement of
Responsibility: 
Wei Zeng, Benjamin Cazzolato, Martin Lambert, Jinzhe Gong, Mark Stephens
Abstract: Acoustic alarm systems using IoT (internet of things) smart sensors (e.g. accelerometers) for leak detection in water networks are rapidly gaining popularity. One of the issues for such systems is the false alarms which often occur as a result of signal contamination by environmental noise, especially by airborne noise resulting in additional vibration. This research proposes a dual-sensor concept for active air-borne noise suppression in accelerometer signals that are excited by both fluid-borne noise (including the leak signal) and air-borne environmental noise. In the proposed arrangement, a microphone adjacent to the measurement station is used to measure the air-borne noise simultaneously to the accelerometer mounted to the pipe. Three methods have been applied in this paper: 1) using the non-coherent output power (NCOP) between the accelerometer and microphone signals; 2) using a Wiener filter; and 3) using adaptive least mean square (LMS) filters together with adaptive infinite impulse response (IIR) filters. Field tests have been carried out on a cast iron water main embedded in a water distribution system. A speaker was used to generate air-borne noise around the measurement station and to excite unwanted vibrations in the pipe. The results show that all three methods can effectively suppress air-borne noise from the accelerometer signals mounted to the pipe. A noise reduction of 30 dB can be achieved using the NCOP in the frequency domain or using the Wiener filter in the time domain. The adaptive filters are relatively less effective and the effectiveness reduces with the increase in bandwidth of the airborne noise. However, the adaptive filters have the potential to be applied online for real-time processing.
Keywords: Leak detection; Pipe break; Noise suppression; Smart water network; Water distribution system
Rights: © 2022 Elsevier Ltd. All rights reserved.
DOI: 10.1016/j.apacoust.2022.108982
Grant ID: http://purl.org/au-research/grants/arc/180100569
Published version: http://dx.doi.org/10.1016/j.apacoust.2022.108982
Appears in Collections:Civil and Environmental Engineering publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.