Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/43682
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Good agreement between bioelectrical impedance and dual-energy X-ray absorptiometry for estimating changes in body composition during weight loss in overweight young women
Author: Thomson, R.
Brinkworth, G.
Buckley, J.
Noakes, M.
Clifton, P.
Citation: Clinical Nutrition, 2007; 26(6):771-777
Publisher: Churchill Livingstone
Issue Date: 2007
ISSN: 0261-5614
1532-1983
Statement of
Responsibility: 
Rebecca Thomson, Grant D. Brinkworth, Jonathan D. Buckley, Manny Noakes and Peter M. Clifton
Abstract: <h4>Aims</h4>To compare estimations of body composition using two different methods of bioelectrical impedance analysis (BIA) with dual X-ray absorptiometry (DXA) for estimating body composition during weight loss in overweight and obese young females.<h4>Methods</h4>Twenty-four overweight or obese females (age 29.5+/-6.1 years, BMI 36.4+/-4.3 kg/m(2)) had body composition assessed using single-frequency (Tanita Ultimate Scale; SF-BIA) and multi-frequency (Impedimed SFB7; MF-BIA) BIA and DXA before and after a 10-week weight loss intervention.<h4>Results</h4>MF-BIA estimates of body composition showed good absolute agreement with DXA, as evidenced by the small biases in the estimation of fat free mass (FFM), fat mass (FM) and percentage body fat (BF%); however, the limits of agreement for each variable were wide (bias +/-1.96 standard deviation; FFM -1.6+/-6.5 kg, FM 1.6+/-6.5 kg, BF% 1.4+/-6.3%). SF-BIA exhibited a larger bias with wide limits of agreement (FFM 3.8+/-9.1 kg, FM -3.8+/-9.1 kg, BF% -4.37+/-10.3%). During weight loss the values provided by MF-BIA and SF-BIA were not significantly different from DXA (p> or =0.89) due to small bias and the limits of agreement were narrow (MF-BIA: FFM -0.01+/-3.74 kg, FM 0.01+/-3.74 kg, BF% 0.22+/-3.40%; SF-BIA: FFM 0.40+/-3.92 kg, FM -0.40+/-3.92 kg, BF% 0.25+/-3.40%).<h4>Conclusion</h4>Compared with DXA, both the MF-BIA and SF-BIA accurately assessed changes in body composition with weight loss but, compared with SF-BIA, MF-BIA provided superior cross-sectional estimates of body composition.
Keywords: Adipose Tissue
Humans
Obesity
Weight Loss
Absorptiometry, Photon
Analysis of Variance
Sensitivity and Specificity
Cross-Sectional Studies
Reproducibility of Results
Body Composition
Electric Impedance
Adolescent
Adult
Female
Overweight
Description: Copyright © 2007 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism All rights reserved.
DOI: 10.1016/j.clnu.2007.08.003
Description (link): http://www.elsevier.com/wps/find/journaldescription.cws_home/623017/description#description
Published version: http://dx.doi.org/10.1016/j.clnu.2007.08.003
Appears in Collections:Aurora harvest 6
Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.