Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/61996
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Assessment of normal tissue complications following prostate cancer irradiation: Comparison of radiation treatment modalities using NTCP models
Author: Takam, R.
Bezak, E.
Yeoh, E.
Marcu, L.
Citation: Medical Physics, 2010; 37(9):5126-5137
Publisher: Amer AssocPhysicists Amer Inst Physics
Issue Date: 2010
ISSN: 0094-2405
2473-4209
Statement of
Responsibility: 
Rungdham Takam and Eva Bezak, Eric E. Yeoh, Loredana Marcu
Abstract: <h4>Purpose</h4>Normal tissue complication probability (NTCP) of the rectum, bladder, urethra, and femoral heads following several techniques for radiation treatment of prostate cancer were evaluated applying the relative seriality and Lyman models.<h4>Methods</h4>Model parameters from literature were used in this evaluation. The treatment techniques included external (standard fractionated, hypofractionated, and dose-escalated) three-dimensional conformal radiotherapy (3D-CRT), low-dose-rate (LDR) brachytherapy (I-125 seeds), and high-dose-rate (HDR) brachytherapy (Ir-192 source). Dose-volume histograms (DVHs) of the rectum, bladder, and urethra retrieved from corresponding treatment planning systems were converted to biological effective dose-based and equivalent dose-based DVHs, respectively, in order to account for differences in radiation treatment modality and fractionation schedule.<h4>Results</h4>Results indicated that with hypofractionated 3D-CRT (20 fractions of 2.75 Gy/fraction delivered five times/week to total dose of 55 Gy), NTCP of the rectum, bladder, and urethra were less than those for standard fractionated 3D-CRT using a four-field technique (32 fractions of 2 Gy/fraction delivered five times/week to total dose of 64 Gy) and dose-escalated 3D-CRT. Rectal and bladder NTCPs (5.2% and 6.6%, respectively) following the dose-escalated four-field 3D-CRT (2 Gy/fraction to total dose of 74 Gy) were the highest among analyzed treatment techniques. The average NTCP for the rectum and urethra were 0.6% and 24.7% for LDR-BT and 0.5% and 11.2% for HDR-BT.<h4>Conclusions</h4>Although brachytherapy techniques resulted in delivering larger equivalent doses to normal tissues, the corresponding NTCPs were lower than those of external beam techniques other than the urethra because of much smaller volumes irradiated to higher doses. Among analyzed normal tissues, the femoral heads were found to have the lowest probability of complications as most of their volume was irradiated to lower equivalent doses compared to other tissues.
Keywords: brachytherapy
cancer
dosimetry
NTCP models
prostate radiotherapy
Rights: © 2010 American Association of Physicists in Medicine
DOI: 10.1118/1.3481514
Published version: http://dx.doi.org/10.1118/1.3481514
Appears in Collections:Aurora harvest 5
Physics publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.