Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/68296
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorOmari, T.-
dc.contributor.authorDejaeger, E.-
dc.contributor.authorVan Beckevoort, D.-
dc.contributor.authorGoeleven, A.-
dc.contributor.authorde Cock, P.-
dc.contributor.authorHoffman, I.-
dc.contributor.authorSmet, M.-
dc.contributor.authorDavidson, G.-
dc.contributor.authorTack, J.-
dc.contributor.authorRommel, N.-
dc.date.issued2011-
dc.identifier.citationAmerican Journal of Gastroenterology, 2011; 106(10):1796-1802-
dc.identifier.issn0002-9270-
dc.identifier.issn1572-0241-
dc.identifier.urihttp://hdl.handle.net/2440/68296-
dc.description.abstractOBJECTIVES: This validation study evaluates a new manometry impedance-based approach for the objective assessment of pharyngeal function relevant to postswallow bolus residue. METHODS: We studied 23 adult and pediatric dysphagic patients who were all referred for a videofluoroscopy, and compared these patients with 10 adult controls. The pharyngeal phase of swallowing of semisolid boluses was recorded with manometry and impedance. Fluoroscopic evidence of postswallow bolus residue was scored. Pharyngeal pressure impedance profiles were analyzed. Computational algorithms measured peak pressure (Peak P), pressure at nadir impedance (PNadImp), time from nadir impedance to PeakP (PNadImp–PeakP), the duration of impedance drop in the distal pharynx (flow interval), upper esophaghageal sphincter (UES) relaxation interval (UES-RI), nadir UES pressure (NadUESP), UES intrabolus pressure (UES-IBP), and UES resistance. A swallow risk index (SRI) was derived by the formula: SRI=(FI × PNadImp)/(PeakP × (TNadImp-PeakP+1)) × 100. RESULTS: In all, 76 patient swallows (35 with residue) and 39 control swallows (12 with residue) were analyzed. Different functional variables were found to be altered in relation to residue. In both controls and patients, flow interval was longer in relation to residue. In controls, but not patients, residue was associated with an increased PNadImp (suggestive of increased pharyngeal IBP). Controls with residue had increased UES-IBP, NadUESP, and UES resistance compared with patients with residue. Residue in patients was related to a prolonged UES-RI. The SRI was elevated in relation to residue in both controls and patients and an average SRI of 9 was optimally predictive of residue (sensitivity 75% and specificity 80%). CONCLUSIONS: We present novel findings in control subjects and dysphagic patients showing that combined manometry and impedance recordings can be objectively analyzed to derive pressure-flow variables that are altered in relation to the bolus residual and can be combined to predict ineffective pharyngeal swallowing.-
dc.description.statementofresponsibilityTaher I. Omari, Eddy Dejaeger, Dirk Van Beckevoort, Ann Goeleven, Paul De Cock, Ilse Hoffman, Maria H. Smet, Geoffrey P. Davidson, Jan Tack and Nathalie Rommel-
dc.language.isoen-
dc.publisherBlackwell Publishing Ltd-
dc.rights© 2011 by the American College of Gastroenterology-
dc.source.urihttp://dx.doi.org/10.1038/ajg.2011.143-
dc.subjectPharynx-
dc.subjectEsophagus-
dc.subjectHumans-
dc.subjectDeglutition Disorders-
dc.subjectVelopharyngeal Insufficiency-
dc.subjectFluoroscopy-
dc.subjectPredictive Value of Tests-
dc.subjectManometry-
dc.subjectElectric Impedance-
dc.subjectDeglutition-
dc.subjectPressure-
dc.subjectAdolescent-
dc.subjectAdult-
dc.subjectAged-
dc.subjectAged, 80 and over-
dc.subjectMiddle Aged-
dc.subjectChild-
dc.subjectChild, Preschool-
dc.subjectFemale-
dc.subjectMale-
dc.subjectRespiratory Aspiration-
dc.titleA novel method for the nonradiological assessment of ineffective swallowing-
dc.typeJournal article-
dc.identifier.doi10.1038/ajg.2011.143-
pubs.publication-statusPublished-
dc.identifier.orcidOmari, T. [0000-0001-5108-7378]-
Appears in Collections:Aurora harvest 5
Paediatrics publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.