Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/68325
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWood, J.-
dc.contributor.authorPlunkett, M.-
dc.contributor.authorPrevin, V.-
dc.contributor.authorChidlow, G.-
dc.contributor.authorCasson, R.-
dc.date.issued2011-
dc.identifier.citationLasers in Surgery and Medicine, 2011; 43(6):499-510-
dc.identifier.issn0196-8092-
dc.identifier.issn1096-9101-
dc.identifier.urihttp://hdl.handle.net/2440/68325-
dc.description.abstractBackground and Objectives: Thermal lasers are routinely used to treat certain retinal disorders although they cause collateral damage to photoreceptors. The current study evaluated a confined, non-conductive thermal, 3-nanosecond pulse laser in order to determine how to produce the greatest therapeutic range without causing collateral damage. Data were compared with that obtained from a standard thermal laser. Materials and Methods: Porcine ocular explants were used; apposed neuroretina was also in place for actual laser treatment. After treatment, the retina was removed and a calcein-AM assay was used to assess retinal pigmented epithelium (RPE) cell viability in the explants. Histological methods were also employed to examine lased transverse explant sections. Three nanoseconds pulse lasers with either speckle- or gaussian-beam profile were employed in the study. Comparisons were made with a 100 milliseconds continuous wave (CW) 532 nm laser. The therapeutic energy range ratio was defined as the minimum visible effect threshold (VET) versus the minimum detectable RPE kill threshold. Results: The 3-nanosecond lasers produced markedly lower minimum RPE kill threshold levels than the CW laser (e.g., 36 mJ/cm2 for speckle-beam and 89 mJ/cm2 for gaussian-beam profile nanosecond lasers vs. 7,958 mJ/cm2 for CW laser). VET values were also correspondingly lower for the nanosecond lasers (130 mJ/cm2 for 3 nanoseconds speckle-beam and 219 mJ/cm2 for gaussian-beam profile vs. 1,0346 mJ/cm2 for CW laser). Thus, the therapeutic range ratios obtained with the nanosecond lasers were much more favorable than that obtained by the CW laser: 3.6:1 for the speckle-beam and 2.5:1 for the gaussian-beam profile 3-nanosecond lasers versus 1.3:1 for the CW laser. Conclusions: Nanosecond lasers, particularly with a speckle-beam profile, provide a much wider therapeutic range of energies over which RPE treatment can be performed, without damage to the apposed retina, as compared with conventional CW lasers. These results may have important implications for the treatment of retinal disease.-
dc.description.statementofresponsibilityJohn P.M. Wood, Malcolm Plunkett, Victor Previn, Glyn Chidlow and Robert J. Casson-
dc.language.isoen-
dc.publisherWiley-liss-
dc.rightsCopyright © 2011 Wiley-Liss, Inc.-
dc.source.urihttp://dx.doi.org/10.1002/lsm.21087-
dc.subjectretinal pigment epithelium-
dc.subjectnanosecond laser-
dc.subjectmicrobuble-
dc.subjectmelanosome-
dc.subjectdiabetic macular edema-
dc.titleNanosecond pulse lasers for retinal applications-
dc.typeJournal article-
dc.identifier.doi10.1002/lsm.21087-
pubs.publication-statusPublished-
dc.identifier.orcidChidlow, G. [0000-0001-7371-0239]-
dc.identifier.orcidCasson, R. [0000-0003-2822-4076]-
Appears in Collections:Aurora harvest 5
Opthalmology & Visual Sciences publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.