Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/89563
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRan, R.-
dc.contributor.authorZhang, W.-
dc.contributor.authorCui, B.-
dc.contributor.authorXu, Y.-
dc.contributor.authorHan, Z.-
dc.contributor.authorWu, A.-
dc.contributor.authorLi, D.-
dc.contributor.authorZhang, D.-
dc.contributor.authorWang, C.-
dc.contributor.authorShi, J.-
dc.date.issued2013-
dc.identifier.citationAnalytical Methods: advancing methods and applications, 2013; 5(20):5637-5643-
dc.identifier.issn1759-9660-
dc.identifier.issn1759-9679-
dc.identifier.urihttp://hdl.handle.net/2440/89563-
dc.description.abstractA simple and rapid detection method for deoxynivalenol (DON) is essential for both basic research on its metabolism and applied research on its surveillance and control. In this study, a simple, fast, and efficient method based on a UPLC-TOF-MS system without any clean-up steps was developed for DON detection in human hepatocellular carcinoma cells (Hep G2). The established method was then validated by the determination of its sensitivity, linearity, recovery, precision and stability. The limits of detection for extracellular and intracellular matrices were 25 ng ml−1 while limits of quantitation for both matrices were 50 ng ml−1, respectively. The recoveries of both matrices were acceptable and the stability of the method was acceptable. Within the detection range, the intra- and inter-day RSDs were less than 12%. Finally, the kinetics of DON in both cell pellets and media were measured using the established method, which showed that DON could be taken up by Hep G2 cells quickly but did not accumulate in the cells. This method could be applied for the fast detection of DON in the human cell matrix, facilitating better understanding of the metabolism of DON in vitro, which, in turn, would benefit the monitoring of DON exposure to humans and animals.-
dc.description.statementofresponsibilityRan Ran, Wei Zhang, Bo Cui, Yi Xu, Zheng Han, Aibo Wu, Dawei Li, Dabing Zhang, Canhua Wang and Jianxin Shi-
dc.language.isoen-
dc.publisherRoyal Society of Chemistry-
dc.rights© The Royal Society of Chemistry 2013-
dc.source.urihttp://dx.doi.org/10.1039/c3ay41106k-
dc.titleA simple and rapid method for the determination of deoxynivalenol in human cells by UPLC-TOF-MS-
dc.typeJournal article-
dc.identifier.doi10.1039/c3ay41106k-
pubs.publication-statusPublished-
dc.identifier.orcidZhang, D. [0000-0003-3181-9812]-
Appears in Collections:Agriculture, Food and Wine publications
Aurora harvest 7

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.